Color Screen Double Beam UV Visible Spectrophotometer

Features of Color Screen Double Beam UV/Visible Spectrophotometer

double beam uv visible spectrophotometer, double beam uv/vis spectrophotometer

 7 Inch Color Screen

Users can do the measurement without connecting to PC with the large screen which can display the scanning curve and graph.

Measured values can be stored to Memory Stick 

Measured result can be saved to Excel, txt or picture format (*csv, *qua, *tet, *bmp), which ensures users can edit the test report on PC.

Top-of-Line hardware

32 bits Cortex_M3 processor, clock speed can reach 120M.

Data Store Function

The RAM has the capability of saving 5000 groups of data and 200 curves which can be recalled anytime.

Excellent Auto-calibrated CT Optical System

Imported Long Service Life Lamps

Super PC Software

The software functions include (1)Kinetics (2)Quantitative (3)Wavelength Scan (4)Multi Wavelength Test (5)DNA/Protein Test. 

And the software can be remotely updated.

N6000Plus Double Beam UV/Vis Spectrophotometer

Technical Parameters of N6000Plus Double Beam UV/Vis Spectrophotometer

 

  1. Optical System: Double Beam, Czerny-Turner (1200L/mm Grating)
  2. Wavelength Range: 190-1100nm
  3. Wavelength Accuracy: +/-0.3nm
  4. Bandwidth: 1nm
  5. Wavelength Repeatability: <=0.1nm
  6. Wavelength Set: Automatic
  7. Work Mode: T. A. C
  8. Photometric Range: 0-200%T, -0.3-3.0A, 0-9999C(0-9999F)
  9. Photometric Accuracy: +/-0.3%T
  10. Stability: +/-0.001A/H @500nm
  11. Stray Light: <=0.05%T
  12. Display Mode: 7" Graphic LCD Screen (Resolution 800 x 400)
  13. Detector: Silicon Photodiode
  14. Interface: USB

Enquiry

N6000 Double Beam UV/Vis Spectrophotometer

Technical Parameters of N6000 Double Beam UV/Vis Spectrophotometer

 

  1. Optical System: Double Beam, Czerny-Turner (1200L/mm Grating)
  2. Wavelength Range: 190-1100nm
  3. Wavelength Accuracy: +/-0.3nm
  4. Bandwidth: 2nm
  5. Wavelength Repeatability: <=0.1nm
  6. Wavelength Set: Automatic
  7. Work Mode: T. A. C
  8. Photometric Range: 0-200%T, -0.3-3.0A, 0-9999C(0-9999F)
  9. Photometric Accuracy: +/-0.3%T
  10. Stability: +/-0.001A/H @500nm
  11. Stray Light: <=0.05%T
  12. Display Mode: 7" Graphic LCD Screen (Resolution 800 x 400)
  13. Detector: Silicon Photodiode
  14. Interface: USB

Enquiry

New Design DOUBLE BEAM UV/Vis Spectrophotometer

Features of New Design Double Beam UV/Vis Spectrophotometer

double beam uv/vis spectrophotometer, spectrophotometer with xenon lamp

  1. The Spectrophotometer can do that is open-use, efficient operation. Preheating Not needed. User no need to wait 30 minutes preheating time like operating a spectrophotometer equiped with W and D2 Lamp. (For U8 )
  2. 7” TFT screen, which can display the spectrums and curves without connecting to the PC.
  3. Support U-Disk storage. Test result can be transfered to U-Disk (excel, txt, *.csv、*.qua.*.tet,*.bmp), User can edit the test report on PC directly.
  4. Interface: RS232, USB drive, USB Host.
  5. Standard 16 GB Storage, can store 5000 groups test results and 500 curves. (32GB for U8)
  6. ARM11 processor for T2602/T2602S, ARM12 processor for U6/U6S, 32 BITS Cortex_M3 Processor for U8.
  7. Equipped with Photomultiplier Tube which make the spectrophotometer more sensitive(U6/U6S)

T2602 Double Beam UV/Vis Spectrophotometer

Technical Parameter of T2602 Double Beam UV/Vis Spectrophotometer

 

  1. Optical System: Double Beam, Czerny-Turner (1200L/mm Grating)
  2. Wavelength Range: 190-1100nm
  3. Wavelength Accuracy: +/-0.3nm
  4. Bandwidth: 2nm
  5. Wavelength Repeatability: <=0.1nm
  6. Wavelength Set: Automatic
  7. Work Mode: T. A. C
  8. Photometric Range: 0-200%T, -0.3-3.0A, 0-9999C(0-9999F)
  9. Photometric Accuracy: +/-0.3%T
  10. Stability: +/-0.001A/H @500nm
  11. Stray Light: <=0.05%T
  12. Display Mode: 7" Graphic LCD Screen (Resolution 1024X600)
  13. Detector: Silicon Photodiode
  14. Lamp: Tungsten Lamp & Deuterium Lamp
  15. Interface: USB drive, USB host, RS232.
  16. Durable OMRON Keys

Enquiry

T2602S Double Beam UV/Vis Spectrophotometer

Technical Parameter of T2602S Double Beam UV/Vis Spectrophotometer

 

  1. Optical System: Double Beam, Czerny-Turner (1200L/mm Grating)
  2. Wavelength Range: 190-1100nm
  3. Wavelength Accuracy: +/-0.3nm
  4. Bandwidth: 0.5/1/2/4/5nm
  5. Wavelength Repeatability: <=0.1nm
  6. Wavelength Set: Automatic
  7. Work Mode: T. A. C
  8. Photometric Range: 0-200%T, -0.3-3.0A, 0-9999C(0-9999F)
  9. Photometric Accuracy: +/-0.3%T
  10. Stability: +/-0.001A/H @500nm
  11. Stray Light: <=0.05%T
  12. Display Mode: 7" Graphic LCD Screen (Resolution 1024X600)
  13. Detector: Silicon Photodiode
  14. Lamp: Tungsten Lamp & Deuterium Lamp
  15. Interface: USB drive, USB host, RS232.
  16. OMRON Keys

Enquiry

U6 Double Beam UV/Vis Spectrophotometer

Technical Parameters of U6 Spectrophotometer

  1. Optical System: Double Beam, Czerny-Turner (1200L/mm Grating)
  2. Wavelength Range: 190-1100nm
  3. Wavelength Accuracy: +/-0.3nm
  4. Bandwidth: 2nm
  5. Wavelength Repeatability: <=0.1nm
  6. Wavelength Set: Automatic
  7. Work Mode: T. A. C. E
  8. Photometric Range: 0-200%T, -0.3-3.0A, 0-9999C(0-9999F)
  9. Photometric Accuracy: +/-0.3%T
  10. Stability: +/-0.0002A/H @500nm
  11. Stray Light: <=0.01%T
  12. Display Mode: 7" Graphic LCD Screen (Resolution 1024X600)
  13. Detector: Photomultiplier
  14. Lamp: Tungsten  & Deuterium Lamp
  15. Interface: USB drive, USB host, RS232.
  16. Durable OMRON Keys

Enquiry

U6S Double Beam UV/Vis Spectrophotometer

 Technical Parameters of U6S Spectrophotometer

  1. Optical System: Double Beam, Czerny-Turner (1200L/mm Grating)
  2. Wavelength Range: 190-1100nm
  3. Wavelength Accuracy: +/-0.3nm
  4. Bandwidth: 0.1-5nm continually variable
  5. Wavelength Repeatability: <=0.1nm
  6. Wavelength Set: Automatic
  7. Work Mode: T. A. C. E
  8. Photometric Range: 0-200%T, -0.3-3.0A, 0-9999C(0-9999F)
  9. Photometric Accuracy: +/-0.3%T
  10. Stability: +/-0.0002A/H @500nm
  11. Stray Light: <=0.01%T
  12. Display Mode: 7" Graphic LCD Screen (Resolution 1024X600)
  13. Detector: Photomultiplier
  14. Lamp: Tungsten & Deuterium Lamp
  15. Interface: USB drive, USB host, RS232.
  16. Durable OMRON Keys

Enquiry

U8 Double Beam UV/Vis Spectrophotometer

Technical Parameters of U8 Spectrophotometer

  1.  Optical System: Double Beam, built in reference detector
  2. Lamp:Flash Xenon Lamp (1000000000 times, 7 years)
  3. Detector:Silicon photodiode
  4. Slit Bandwidth: 1nm or 2nm optional
  5. Wavelength Range: 190-1100nm
  6. Wavelength Accuracy: ±0.3nm
  7. Wavelength Repeatability: 0.1nm
  8. Wavelength Resolution: 0.1nm
  9. Stray Light: ≤0.05%T@220nm, 360 nm
  10. Photometric Accuracy: ±0.3%T
  11. Photometric Method: T, A, C, E    
  12. Sample Room: Automatic 8 position carrousel
  13. Software: Yes
  14.  Display Mode: 7" Graphic LCD Screen (Resolution 1024X600)  
  15. Interface: USB drive, USB host, RS232.
  16. Durable OMRON Keys

Enquiry

Touch Screen Double Beam UV Visible Spectrophotometer

Features of Touch Screen UV Visible Spectrophotometer

touch screen uv visible spectrophotometer, scanning uv visible spectrophotometer

  1.  10.1” touch screen, which can display the spectrums and curves without connecting to the PC.
  2. Support U-Disk storage. Test result can be transfered to U-Disk (excel, txt, *.csv、*.qua.*.tet,*.bmp), User can edit the test report on PC directly.
  3. Interface: RS232, USB drive, USB Host.
  4. Standard 16 GB Storage, can store 5000 groups test results and 500 curves. 
  5. ARM12 processor for T3202/U7/U7S. 32 bit Cortex_M3 processor for U9.
  6. Optional automatic injection system, which can improve work efficiency.
  7. Equipped with Photomultiplier Tube which make the spectrophotometer moe sensitive(U7/U7S)
  8. Model U9 UV Vis Spectrophotometer equiped with Xenon Lamp, which service life can be over 7 years, lower much cost and energy on maintainence.  And with our original design on Optical, Electrical Circuit and Structure, the spectrophotometer has functions of Photometric, Quantitation, Multiple Wavelength, DNA/Protein, Kinetics, Scanning Spectrum.

T3202 Double Beam UV/Vis Spectrophotometer

Technical Parameters of T3202 Spectrophotometer

 

  1. Optical System: Double Beam, Czerny-Turner (1200L/mm Grating)
  2. Wavelength Range: 190-1100nm
  3. Wavelength Accuracy: +/-0.3nm
  4. Bandwidth: 2nm
  5. Wavelength Repeatability: <=0.1nm
  6. Wavelength Set: Automatic
  7. Work Mode: T. A. C
  8. Photometric Range: 0-200%T, -0.3-3.0A, 0-9999C(0-9999F)
  9. Photometric Accuracy: +/-0.3%T
  10. Stability: +/-0.001A/H @500nm
  11. Stray Light: <=0.05%T
  12. Display Mode: 10.1" touch Screen (Resolution 1024 x 800)
  13. Detector: Silicon Photodiode
  14. Lamp: Tungsten Lamp & Deuterium Lamp
  15. Interface: USB

Enquiry

U7 Double Beam UV/Vis Spectrophotometer

Technical Parameters of U7 Spectrophotometer

 

  1. Optical System: Double Beam, Czerny-Turner (1200L/mm Grating)
  2. Wavelength Range: 190-1100nm
  3. Wavelength Accuracy: +/-0.3nm
  4. Bandwidth: 2nm
  5. Wavelength Repeatability: <=0.1nm
  6. Wavelength Set: Automatic
  7. Work Mode: T. A. C. E
  8. Photometric Range: 0-200%T, -0.3-3.0A, 0-9999C(0-9999F)
  9. Photometric Accuracy: +/-0.3%T
  10. Stability: +/-0.0002A/H @500nm
  11. Stray Light: <=0.01%T
  12. Display Mode: 10.1" Touch Screen (Resolution 1024X800)
  13. Detector: Photomultiplier
  14. Lamp: Tungsten Lamp & Deuterium Lamp
  15. Interface: USB drive, USB host, RS232.

Enquiry

U7S Double Beam UV/Vis Spectrophotometer

Technical Parameter of U7S Spectrophotometer

 

  1. Optical System: Double Beam, Czerny-Turner (1200L/mm Grating)
  2. Wavelength Range: 190-1100nm
  3. Wavelength Accuracy: +/-0.3nm
  4. Bandwidth: 0.1-5nm continually variable
  5. Wavelength Repeatability: <=0.1nm
  6. Wavelength Set: Automatic
  7. Work Mode: T. A. C. E
  8. Photometric Range: 0-200%T, -0.3-3.0A, 0-9999C(0-9999F)
  9. Photometric Accuracy: +/-0.3%T
  10. Stability: +/-0.0002A/H @500nm
  11. Stray Light: <=0.01%T
  12. Display Mode: 10.1" Touch Screen (Resolution 1024X800)
  13. Detector: Photomultiplier
  14. Lamp: Tungsten Lamp & Deuterium Lamp
  15. Interface: USB drive, USB host, RS232.

Enquiry

U9 Double Beam UV/Vis Spectrophotometer

Technical Parameters of U9 Spectrophotometer

 

  1. Optical System: Double Beam, built in refernce detector
  2. Lamp:Flash Xenon Lamp (1000000000 times, 7 years)
  3. Detector:Silicon photodiode
  4. Slit Bandwidth: 1nm or 2nm optional
  5. Wavelength Range: 190-1100nm
  6. Wavelength Accuracy: ±0.3nm
  7. Wavelength Repeatability: 0.1nm
  8. Wavelength Resolution:0.1nm
  9. Stray Light:≤0.05%T@220nm, 360 nm
  10. Photometric Accuracy: ±0.3%T
  11. Photometric Method: T, A, C, E    
  12. Sample Room:Automatic 8 position carrousel
  13. Software: Yes
  14. Display Mode: 10.1" Touch Screen (Resolution 1024X800)
  15. Interface: USB drive, USB host, RS232.

Enquiry